TelcoFlex® III

<b>Surface Marking:</b> Two sides of the cable shall be printed using an ink of contrasting color and with the following information: "TelcoFlex™ fI/KS24194™ L2 NON-HAL (SIZE) AWG (OR KCMIL) 600V. RHHILS FT4 (UL) OR AWM 3578 VW-1 E18321---A.I.W. CORP.--LL8825 CSA AWM I B 105°C 600V. FT4-ST1 (YEAR) (SEQ. FTG. ON 1 SIDE)". For sizes 1/0 AWG and larger add uFOR CT USE" before "(UL)"  <b>Testing:</b> Physical and electrical tests in accordance with UL Standard 44 requirements.  <br /><b>Labels:</b> UL tags and labels shall be applied to each reel.

Central Office Power Wire and Cable
Class B Stranded With Braid

Low Smoke, Non-Halogenated Insulation With Cotton Braid, Lead-Free and Silicone-Free, UL Listed RHH/LS FT4 and VW-1, 90°C Dry, 60°C Wet – 600 Volts UL Listed “For CT Use” (Sizes 1/0 AWG and Larger) CSA AWM I B 105°C, 600 Volt, FT4

Scope

This specification covers the construction requirements for low smoke, non-halogenated, TelcoHyde™ 5221 insulated, cotton braided power wire and cable, type RHH/LS for use in accordance with the National Electrical Code.

The construction of the wire and cable is in accordance with Underwriters’ Laboratories requirements and the requirements of CSA for the FT4 flame tests. Sizes 1/0 AWG and larger are UL “CT USE” rated.

Construction

Size: 14 AWG through 750 KCMIL – Single conductor

Conductors: Class B stranded tinned copper conforming to ASTM B-33 and B-8 and Underwriters’ Laboratories requirements. An opaque mylar tape shall be applied over the conductor to facilitate stripping.

Insulation: 90°C rated limited smoke, non-halogen, TelcoHyde™ 5221 conforming to Underwriters’
Laboratories Standard 44 and Telcordia Specification GR-347-CORE, also CSA 105°C AWM rated. The insulation has a limiting oxygen index of 35%.

Separator: On sizes 6 AWG and larger a 1 mil clear mylar tape shall be applied over the insulation.

Covering: On all sizes a natural cotton braid conforming to UL requirements is applied overall. A section of completed cable has a limiting oxygen index of 35%.

Finish: A moisture resistant, flame retardant saturant and a colored finisher is applied to the braid.

Separator: On sizes 6 AW

Surface Marking: Two sides of the cable shall be printed using an ink of contrasting color and with the following information: “TelcoFlex™ III/KS24194™ L3 NON-HAL (SIZE) AWG (OR KCMIL) 600V. RHH/LS FT4 (UL) OR AWM 3578 VW-1 E18321—A.I.W. CORP.—LL8825 CSA AWM I B 105°C 600V. FT4 (YEAR) (SEQ. FTG. ON 1 SIDE)”.

For sizes 1/0 AWG and larger add “FOR CT USE” before “(UL)”

Testing: Physical and electrical tests in accordance with UL Standard 44 requirements.

Labels: UL tags and labels shall be applied to each reel.

Cable Data

PART NUMBER SIZE AWG OR KCMIL STRANDING INSULATION MIN. AVG. WALL (MILS) NOMINAL INSULATION DIAMETER (INCHES) NOMINAL OVERALL DIAMETER (INCHES) MAX D.C. RES. @ 20° C (OHMS/M FT.) STOCK COLOR* APPROX WEIGHT LBS./M FT.
39757 14 7/.0242” 45 .165 .200 2.730 Gray 31
39758 12 7/.0305” 45 .185 .220 1.720 Gray 41
39759 10 7/.0385” 45 .210 .250 1.080 Gray 59
39760 8 7/.0486″ 60 .270 .320 0.678 Gray 92
39761 6 7/.0612″ 60 .305 .355 0.427 Gray 130
39762 4 7/.0772″ 60 .350 .400 0.269 Gray 190
39763 2 7/.0974″ 60 .410 .460 0.169 Gray 282
39764 1/0 19/.0745″ 80 .530 .585 0.106 Gray 443
39765 2/0 19/.0837″ 80 .575 .630 0.084 Gray 538
39766 4/0 19/.1055″ 80 .680 .735 0.052 Gray 812
39767 350 37/.0973″ 95 .860 .915 0.032 Gray 1313
39768 500 37/.1162″ 95 .990 1.045 0.022 Gray 1822
39769 750 61/.1109″ 110 1.200 1.260 0.0148 Gray 2692

*Also available in black, blue, green, red and with black tracer; consult factory.

Rail and Transit

Exane® 1068A-2000V
Exane® ZH V15
Exane® 1069A/1093
Exane® 1068A-600V
Exane® 1062
Exane® 15 MCSU 600V
Exane® 15 RD 600V

Telecommunications

TelcoFlex® II
TelcoFlex® III
TelcoFlex® IV
TelcoSafe® 13949 I
TelcoSafe® 13950 E

Central Office

Switchboard 85
Switchboard 100Ohm
T100 Central Office
1249C Central Office
600C Central Office



Download this Sheet as a PDF

Adobe Reader required.