Exane®ZH-1105A 1800/3000V Metric

Zero Halogen 125°C* Transit Wire

1800/3000 VOLT Metric

WARNING: California Proposition 65 – Cancer and Reproductive Harm.
www.P65Warnings.ca.gov
 

Scope

Exane®-ZH, Low Smoke Zero Halogen transit wire is a tough, highly flame retardant construction ideally suited for use in rugged locomotive and transportation industry applications. It has excellent electrical characteristics combined with superior mechanical, heat, moisture, oil, chemical and abrasion properties. This wire should be considered for applications where flame resistance and low levels of off gassing and toxic fumes are required.

Features

• Superior Flame Retardence
• Exceptional wet electrical properties
• Enhanced Mechanical toughness
• Wide temperature range –45°C to 125°C
• Thermoset Insulation
• Excellent oil/solvent resistance
• Sunlight resistant
• Low Smoke
• Zero Halogen

Performance Standards

• Satisfies performance requirements of BS EN 50265-2-1: 1999 (IEC 60332-2-2: 2004)
• Satisfies performance requirements of BS EN 50265-2-2:1999 (IEC 60332-2-1: 2004)
• Satisfies the requirements for BS 6853:1999 vehicle category 1a for vehicles interior and exterior per:
− BS 6853: 1997 Annex D 8.7
− BS 6853: 1999, Clause 6.2, Table 13&14
− BS 6853: 1999 Annex B.1
• Satisfies performance requirements of IEC 60754-1
• Satisfies performance requirements of IEC 60754-2

Construction

Conductor: Annealed, Tinned copper per ASTM B33, B172, AAR S-501, and AAR RP-585

Insulation: Crosslinked polyolefin, Exane® (colors – as required)

* Rockbestos-Surprenant rated 125°C, 130°C overload, 250°C short circuit

Conductor (mm²) Conductor Construction (#/mm Dia) Conductor Diameter (mm) (AWG) Nominal Wall Thickness (mm) Nominal Ins. Diameter (mm) DCR Weight (kg/100m) Bend Radius (mm)
0.75 19/0.20 1.19 1.14 2.74 26.70 1.64 10.96
1 32/0.20 1.29 1.14 2.87 20.00 1.64 11.48
1.5 30/0.25 1.52 1.14 3.88 13.70 2.98 15.52
2.5 50/0.25 1.93 1.14 4.29 8.21 4.02 17.16
4 56/0.30 2.46 1.14 4.82 5.09 5.81 19.28
6 84/0.30 3.17 1.14 5.53 3.39 8.20 22.12
10 80/0.40 3.93 1.40 6.80 1.95 13.12 27.20
16 133/0.40 5.59 1.40 8.45 1.24 19.97 33.80
25 203/0.40 6.55 1.40 9.42 0.795 29.22 37.68
35 280/0.40 8.25 1.65 11.66 0.57 41.29 46.64
50 399/0.40 9.78 1.65 13.18 0.39 56.65 52.72
70 361/0.50 11.68 1.65 15.08 0.28 77.97 60.32
95 475/0.50 13.33 1.65 16.73 0.21 102.12 66.92
150 741/0.50 17.02 1.90 20.45 0.132 160.42 81.80
185 962/0.50 19.05 1.90 22.99 0.108 196.50 91.16
240 1184/0.50 21.59 1.90 25.53 0.0817 251.21 102.12
300 1480/0.50 24.257 2.29 28.95 0.0654 316.37 115.80
400 1961/0.50 27.94 2.29 32.64 0.0495 417.45 130.56

* According to ICEA 5-66-524
** According to IEC 60228

1. The Exane® insulation family has outstanding mechanical and electrical test characteristics. It also has excellent long-term moisture resistance and heat aging characteristics. See the above specification for details.
2. Normal stock color is dark grey. Striping is also available.

* These ampacities are based on single conductors in air with an ambient of 40°C and conductor temperature of 110°C.

Rail and Transit

Exane®1093
Exane® TFE Fluoropolymer
Exane®Transit 600V
2KV-DLO
Exane® 1068A-600V
Exane® 1068A-2000V
Exane®-1069A
Exane®-15 1168B Multi-Conductor 600V
Exane® Case Wire
Exane® 15 Reduced Dia. 600V
Exane® ZH-1105A 600V
Exane®ZH-1105A 2000V
Exane®ZH-1105A 600/1000V Metric
Exane®ZH-1105A 1800/3000V Metric
Exane®ZH-1105A 1800V/3000V Metric
1KV-DLO

Telecommunications

TelcoSafe® LIST 1
TelcoSafe® LIST 2
Intra-Bay Wiring
TelcoFlex® II
TelcoFlex® III
TelcoFlex® IV

Data

Exane® RS-485
Exane® CAT 6 4 Pairs 24 AWG
Exane®Cat 5E 4 Pairs 24 AWG
Exane® CAT 5E 2 Pairs 22 AWG
Exane® MVB/WTB 4C 20 AWG
Exane® MVB/WTB 2C 20 AWG

Exane Compliance Certification

Download this Sheet as a PDF

Adobe Reader required.