Exane®ZH-1105A 1800V/3000V Metric

Transit Wire, 1800V-3000V

125°C • Transit Wire • 1800V – 3000V
Spec. DAA1105A

WARNING: California Proposition 65 – Cancer and Reproductive Harm.
www.P65Warnings.ca.gov
 

Scope

Exane®-ZH, Low Smoke Zero Halogen transit wire is a tough, highly flame retardant construction ideally suited for use in rugged locomotive and transportation industry applications. It has excellent electrical characteristics combined with superior mechanical, heat, moisture, oil, chemical and abrasion properties. This wire should be considered for applications where flame resistance and low levels of off gassing and toxic fumes are required.

Features

• Superior Flame Retardance
• Exceptional wet electrical properties
• Enhanced Mechanical toughness
• Wide temperature range -45°C to 125°C
• Thermoset Insulation
• Excellent oil/solvent resistance
• Sunlight resistant
• Low Smoke
• Zero Halogen

Performance Standards

• Satisfies performance requirements of BS EN 50265-2-1: 1999 (IEC 60332-2-2: 2004)
• Satisfies performance requirements of BS EN 50265-2-2:1999 (IEC 60332-2-1: 2004)
• Satisfies the requirements for BS 6853:1999 vehicle category 1a for vehicles interior and exterior per:
− BS 6853: 1997 Annex D 8.7
− BS 6853: 1999, Clause 6.2, Table 13&14
− BS 6853: 1999 Annex B.1

Construction

Conductor: Annealed, Tinned copper per ASTM B33, B172, AAR S-501, and AAR RP-585
Insulation: Crosslinked polyolefin, Exane® (colors-as required)
* RSCC rated 125°C, 130°C overload, 250°C short circuit

Conductor

mm²

Conductor

Construction

#/mm Dia

Conductor Diameter

mm

Nominal Wall

Thickness

mm

Nominal Ins.

Diameter

mm

DCR**

Ω/km

Weight

KG/100 M)

Blend Radius

mm

0.75

19/0.20

1.19

1.14

2.74

26.70

1.64

10.96

1

32/0.20

1.29

1.14

2.87

20.00

1.64

11.48

1.5

30/0.25

1.52

1.14

3.88

13.70

2.98

15.52

2.5

50/0.25

1.93

1.14

4.29

8.21

4.02

17.16

4

56/0.30

2.46

1.14

4.82

5.09

5.81

19.28

6

84/0.30

3.17

1.14

5.53

3.39

8.20

22.12

10

80/0.40

3.93

1.40

6.80

1.95

13.12

27.20

16

133/0.40

5.59

1.40

8.45

1.24

19.97

33.80

25

203/0.40

6.55

1.40

9.42

0.795

29.22

37.68

35

280/0.40

8.25

1.65

11.66

0.57

41.29

46.64

50

399/0.40

9.78

1.65

13.18

0.39

56.65

52.72

70

361/0.50

11.68

1.65

15.08

0.28

77.97

60.32

95

475/0.50

13.33

1.65

16.73

0.21

102.12

66.92

150

741/0.50

17.02

1.90

20.45

0.132

160.42

81.80

185

962/0.50

19.05

1.90

22.99

0.108

196.50

91.16

240

1184/0.50

21.59

1.90

25.53

0.0817

251.21

102.12

300

1480/0.50

24.257

2.29

28.95

0.0654

316.37

115.80

400

1961/0.50

27.94

2.29

32.64

0.0495

417.45

130.56

*According to ICEA 5-66-524.
**According to IEC 60228.

Striping is available.

 

Exane® is a registered trademark RSCC Wire & Cable LLC

 

 

Rail and Transit

Exane®1093
Exane® TFE Fluoropolymer
Exane®Transit 600V
2KV-DLO
Exane® 1068A-600V
Exane® 1068A-2000V
Exane®-1069A
Exane®-15 1168B Multi-Conductor 600V
Exane® Case Wire
Exane® 15 Reduced Dia. 600V
Exane® ZH-1105A 600V
Exane®ZH-1105A 2000V
Exane®ZH-1105A 600/1000V Metric
Exane®ZH-1105A 1800/3000V Metric
Exane®ZH-1105A 1800V/3000V Metric
1KV-DLO

Telecommunications

TelcoSafe® LIST 1
TelcoSafe® LIST 2
Intra-Bay Wiring
TelcoFlex® II
TelcoFlex® III
TelcoFlex® IV

Data

Exane® RS-485
Exane® CAT 6 4 Pairs 24 AWG
Exane®Cat 5E 4 Pairs 24 AWG
Exane® CAT 5E 2 Pairs 22 AWG
Exane® MVB/WTB 4C 20 AWG
Exane® MVB/WTB 2C 20 AWG

Exane Compliance Certification