Exane® RS-485

2C 20 AWG, NFPA 130 Compliant

90°C • 100 Ohms • Low Smoke Zero Halogen • Train Car Application
RS-422 • RS-232 • LON • Fieldbus • TD-010002

WARNING: California Proposition 65 – Cancer and Reproductive Harm.
www.P65Warnings.ca.gov
 

Scope

Exane® RS-485 TD-010002 is designed to operate on train cars, LRV, and people mover applications. It employs a rugged thermoset low smoke halogen free jacket compound. The thermoset jacket provides superior resistance to abrasion, fire, and moisture. It may be installed in wet or dry locations. The cable complies with train cars specifications such as NFPA 130, ICEA S-19-81, ASTM E662, BSS 7239 and parts of RP-585.

Features

• Thermoset LSHF Insulation and Jacket
• Superior mechanical properties
• Ruggedized construction, excellent mechanical toughness
• Operating temperature -40°C to 90°C
• Passes temperature cycling test -30°C to +125°C, 250 cycles
• Ozone resistance
• Tested to the following RP-585 tests: Abrasion test,
• Notch Propagation, Crush, 26 weeks long term water, Cut through

Performance Standards

• EIA/TIA 568-C.2 for Category 6 cables
• Passes the spread of fire and smoke emissions test requirements for low voltage wire and cable in accordance with NFPA 130-2014 Article 8.6.7.1.1 for transit vehicle application. Passes UL 1685 flame test with IEEE 1202/FT4 Flame Method and smoke measurement.
• Passes the flame test requirement of 49 Code of Federal Regulations (CFR), Part 238 Appendix B, in accordance with NEMA WC3/ICEA S-19-81, paragraph 6.19.6.
• Passes the smoke test requirement of 49 Code of Federal Regulations (CFR), Part 238, Appendix B, in accordance with ASTM E662-97.
• Passes Toxicity Test requirements when tested in accordance with Boeing Specification Support Standard (BSS) 7239.
• ROHS and Reach compliant

Construction

Conductor: Stranded Tin Copper 20 AWG (19/32)
Insulation: Cross-Linked Low Smoke Halogen Free
Color Code: Yellow White
Pairs: Two Conductors twisted together
Shield: Tape Shield
Braid: 36 AWG, Tin Copper
Outer Jacket: Black, Cross-Linked Low Smoke Halogen Free Jacket

*Typical installation employs M12 connector, contact Electro Wire for more information.

EXANE RS-485 TD-010002, 2C 20 AWG

Part Number

Number of

Conductors

Conductor

Stranding

Conductor

Size

MILS

Insulated

Cond. Size

MILS

Jacket Wall

MILS

Overall

Size

IN

Weight

LBS/

1000 FT

Bend

Radius

IN

2

19/32

38

100

35

0.340

65

2.8/5.7

Exane® is a registered trademark RSCC Wire & Cable LLC

 

Rail and Transit

Exane®1093
Exane® TFE Fluoropolymer
Exane®Transit 600V
2KV-DLO
Exane® 1068A-600V
Exane® 1068A-2000V
Exane®-1069A
Exane®-15 1168B Multi-Conductor 600V
Exane® Case Wire
Exane® 15 Reduced Dia. 600V
Exane® ZH-1105A 600V
Exane®ZH-1105A 2000V
Exane®ZH-1105A 600/1000V Metric
Exane®ZH-1105A 1800/3000V Metric
Exane®ZH-1105A 1800V/3000V Metric
1KV-DLO

Telecommunications

TelcoSafe® LIST 1
TelcoSafe® LIST 2
Intra-Bay Wiring
TelcoFlex® II
TelcoFlex® III
TelcoFlex® IV

Data

Exane® RS-485
Exane® CAT 6 4 Pairs 24 AWG
Exane®Cat 5E 4 Pairs 24 AWG
Exane® CAT 5E 2 Pairs 22 AWG
Exane® MVB/WTB 4C 20 AWG
Exane® MVB/WTB 2C 20 AWG

Exane Compliance Certification

Download this Sheet as a PDF

Adobe Reader required.