Exane®-15 1168B Multi-Conductor 600V

EXANE – TRANSIT Multi-Conductor Cable

125°C • Multi-Conductor Cable • 600V
Shielded • Unshielded • Spec. DAC1168B

WARNING: California Proposition 65 – Cancer and Reproductive Harm.
www.P65Warnings.ca.gov
 

Scope

Exane® multi-conductor transit cables are a rugged, flame retardant construction. They are suitable for installation indoors or outdoors in metals trays, conduit, underground duct, or for direct burial. The cables have excellent flexibility and resist crush, low temperature cracking, moisture and petrochemical fluids. The Exane® thermoset insulation system provides a conductor component with superior cut-through, abrasion resistance and electrical overload characteristics.

Features

• Wide insulated conductor temperature range -55°C to 125°C
• Light weight
• Superior mechanical properties
• Flexible construction
• Flame retardant
• Low smoke
• Excellent fluid/oil resistance
• Moisture and sunlight resistant
• RoHS Compliant

Performance Standards

• Meets all requirements of RSCC Spec. DAC 1168B
• Passes the spread of fire and smoke emission in accordance with NFPA 130-2014 article 8.6.7.11 • FT4/IEEE1202 with smoke per UL 1685
• Single conductors pass UL VW-1 flame test

Construction

Conductor: Annealed, tinned copper per ASTM B33, B172, AAR S-501, and AAR RP-585
Insulation: Exane® 15 crosslinked polyolefin with crosslinked modified fluoropolymer jacket
Color Code: As specified by customer
Fillers: When required, flame retardant and non-hygroscopic
Shield: Tin copper braid or as specified by customer
Binder Tape: Non-hygroscopic and non-wicking
Jacket: Exane® crosslinked polyolefin
* RSCC rated 125°C, 130°C overload, 250°C short circuit

Scope

Exane®-15 reduced diameter multiconductor transit cable is ideally suited to operate in the confined spaces of today’s transit vehicles. They are designed to operate inside equipment, in trays, conduit, raceways and other areas of the vehicle where space is limited. These cables have excellent flexibility, flame, crush, oil and moisture resistance. They are available in both unshielded and shielded constructions.

Product Number

Number of

Conductors

AWG

mm²

Stranding

Insulated

Conductor OD

In

Jacket

Thickness

In

Cable OD

In

Weight

LBS/M’

v

2

22

.38

19/34

0.062

0.020

0.168

14.7

RTXE 2/C 20

2

20

.62

19/32

0.070

0.020

0.184

18.8

RTXE 2/C 18

2

18

.96

19/30

0.077

0.020

0.198

23.8

RTXE 2/C 16

2

16

1.23

19/29

0.084

0.020

0.212

28.3

RTXE 2/C 14

2

14

1.94

19/27

0.097

0.020

0.238

39.1

RTXE 2/C 12

2

12

3.08

19/25

0.116

0.020

0.276

56.1

RTXE 2/C 10

2

10

4.74

27/24

0.153

0.020

0.350

90.0

Exane® 15: Two Conductor Cable Shielded with Tinned Copper Braid Shield

RTXE 2/C 22S

2

22

.38

19/34

0.062

0.020

0.190

16.0

RTXE 2/C 20S

2

20

.62

19/32

0.070

0.020

0.206

30.1

RTXE 2/C 18S

2

18

.96

19/30

0.077

0.020

0.220

36.4

RTXE 2/C 16S

2

16

1.23

19/29

0.084

0.020

0.234

41.4

RTXE 2/C 14S

2

14

1.94

19/27

0.097

0.020

0.260

54.7

RTXE 2/C 12S

2

12

3.08

19/25

0.116

0.020

0.298

73.5

RTXE 2/C 10S

2

10

4.74

27/24

0.153

0.020

0.372

113.0

Exane® 15: Three Conductor Cable Unshielded

RTXE 3/C 22

3

22

.38

19/34

0.062

0.020

0.177

19.1

RTXE 3/C 20

3

20

.62

19/32

0.070

0.020

0.194

24.9

RTXE 3/C 18

3

18

.96

19/30

0.077

0.020

0.209

32.1

RTXE 3/C 16

3

16

1.23

19/29

0.084

0.020

0.224

38.6

RTXE 3/C 14

3

14

1.94

19/27

0.097

0.020

0.252

54.4

RTXE 3/C 12

3

12

3.08

19/25

0.116

0.020

0.293

79.1

RTXE 3/C 10

3

10

4.74

27/24

0.153

0.020

0.369

130.0

Exane® 15: Three Conductor Cable Shielded with Tinned Copper Braid Shield

RTXE 3/C 22S

3

22

.38

19/34

0.062

0.020

0.199

19.4

RTXE 3/C 20S

3

20

.62

19/32

0.070

0.020

0.216

37.6

RTXE 3/C 18S

3

18

.96

19/30

0.077

0.020

0.231

46.2

RTXE 3/C 16S

3

16

1.23

19/29

0.084

0.020

0.246

54.0

RTXE 3/C 14S

3

14

1.94

19/27

0.097

0.020

0.274

70.8

RTXE 3/C 12S

3

12

3.08

19/25

0.116

0.020

0.315

97.7

RTXE 3/C 10S

3

10

4.74

27/24

0.153

0.020

0.391

152.0

Exane® is a registered trademark RSCC Wire & Cable LLC

Rail and Transit

Exane®1093
Exane® TFE Fluoropolymer
Exane®Transit 600V
2KV-DLO
Exane® 1068A-600V
Exane® 1068A-2000V
Exane®-1069A
Exane®-15 1168B Multi-Conductor 600V
Exane® Case Wire
Exane® 15 Reduced Dia. 600V
Exane® ZH-1105A 600V
Exane®ZH-1105A 2000V
Exane®ZH-1105A 600/1000V Metric
Exane®ZH-1105A 1800/3000V Metric
Exane®ZH-1105A 1800V/3000V Metric
1KV-DLO

Telecommunications

TelcoSafe® LIST 1
TelcoSafe® LIST 2
Intra-Bay Wiring
TelcoFlex® II
TelcoFlex® III
TelcoFlex® IV

Data

Exane® RS-485
Exane® CAT 6 4 Pairs 24 AWG
Exane®Cat 5E 4 Pairs 24 AWG
Exane® CAT 5E 2 Pairs 22 AWG
Exane® MVB/WTB 4C 20 AWG
Exane® MVB/WTB 2C 20 AWG

Exane Compliance Certification