2KV-DLO

90°C • DLO Rated 2000V
CT Rated UL Listed as Type RHH/RHW-2
CSA Certified as RW90 • RoHS Compliant

WARNING: California Proposition 65 – Cancer and Reproductive Harm.
www.P65Warnings.ca.gov
 

Applications

DLO is especially suited to supply power to traction motors of diesel-electric locomotives. It is also recommended as a portable cable for drilling rigs, on-shore or off-shore, railroad and transit car wiring, electric earth-moving equipment, in shipyard applications, arc welder supply leads, power and control jumper cable, telcom power supply and motor leads. The cable is suitable for use in wet or dry areas, conduits, ducts, troughs or trays, and where superior electrical properties are desired. The maximum continuous conductor temperature for normal operation is 90°C in wet or dry locations. DLO resists oils, acids, alkalines, heat, flame, and has abrasion resistance.

Specifications

    • Made in accordance with UL and CSA Standards
    • MSHA accepted (P-07-KA090026-MSHA)
    • RoHS Compliant
    • UL listed as Type RHH-RHW-2 per UL 44
    • CSA Certified as Type RW90 1kV per C22.2 No.38
    • Meets FT-4 / IEEE 1202 and VW-1 Flame Tests
    • Oil Resistant / Sunlight Resistant / -40°C

      Construction

      Electro Wire DLO Cables are manufactured in sizes 14 AWG through 1111.0 KCMIL with stranded tinned annealed copper. A paper or polyester tape separates the conductor from the EPDM rubber insulation to aid in stripping. A black, heavy duty CPE sunlight resistant jacket is extruded over the insulation.

      Part Number

      AWG

      or

      KCMIL

      Conductor

      Strand

      Nominal

      Insulation

      Thickness

      Nominal

      Jacket

      Thickness

      Nominal

      Overall

      Diameter

      IN

      Current Amps

      Approx.

      Net

      Weight

      LBS/1000’**

      IN

      mm

      IN

      mm

      (1)

      (2)

      DLOC-014-001

      14

      19/0.0147

      0.045

      1.14

      0.015

      0.38

      0.195

      15

      35

      30

      DLOC-012-001

      12

      19/0.0185

      0.045

      1.14

      0.015

      0.38

      0.215

      20

      40

      40

      DLOC-010-001

      10

      19/0.0234

      0.045

      1.14

      0.015

      0.38

      0.240

      40

      55

      60

      DLOC-008-001

      8

      41/24

      0.055

      1.40

      0.030

      0.76

      0.330

      55

      80

      95

      DLOC-006-001

      6

      65/24

      0.060

      1.52

      0.030

      0.76

      0.370

      75

      105

      145

      DLOC-004-001

      4

      105/24

      0.060

      1.52

      0.030

      0.76

      0.420

      95

      140

      205

      DLOC-002-001

      2

      168/24

      0.060

      1.52

      0.030

      0.76

      0.500

      130

      190

      295

      DLOC-001-001

      1

      224/24

      0.080

      2.03

      0.045

      1.14

      0.630

      150

      220

      440

      DLOC-110-001

      1/0

      273/24

      0.080

      2.03

      0.045

      1.14

      0.650

      170

      260

      515

      DLOC-210-001

      2/0

      324/24

      0.080

      2.03

      0.045

      1.14

      0.710

      195

      300

      580

      DLOC-310-001

      3/0

      448/24

      0.080

      2.03

      0.045

      1.14

      0.800

      225

      350

      770

      DLOC-410-001

      4/0

      532/24

      0.080

      2.03

      0.045

      1.14

      0.810

      260

      405

      930

      DLOC-262-001

      262.2

      646/24

      0.090

      2.29

      0.065

      1.65

      0.960

      296

      467

      1130

      DLOC-313-001

      313.3

      775/24

      0.090

      2.29

      0.065

      1.65

      1.030

      326

      522

      1295

      DLOC-373-001

      373.7

      925/24

      0.090

      2.29

      0.065

      1.65

      1.080

      362

      591

      1545

      DLOC-444-001

      444.4

      1110/24

      0.090

      2.29

      0.065

      1.65

      1.160

      400

      652

      1820

      DLOC-535-001

      535.3

      1332/24

      0.090

      2.29

      0.065

      1.65

      1.200

      445

      728

      2195

      DLOC-646-001

      646.4

      1591/24

      0.090

      2.29

      0.065

      1.65

      1.280

      493

      815

      2560

      DLOC-777-001

      777.7

      1924/24

      0.090

      2.29

      0.065

      1.65

      1.360

      545

      904

      3050

      DLOC-1111-001

      1111.0

      2745/24

      0.115

      2.92

      0.095

      2.41

      1.760

      640

      1115

      4187

      * (1) Ampacities based on 90°C Conductor and 30°C Ambient temperature based on 2011 National Electric Code 310.15 for not                  more than three current-carrying conductors in a raceway, cable or earth.
      * (2) Ampacities based on single-conductor in free air in accordance with 2011 National Electrical Code 310.15.

      Rail and Transit

      Exane®1093
      Exane® TFE Fluoropolymer
      Exane®Transit 600V
      2KV-DLO
      Exane® 1068A-600V
      Exane® 1068A-2000V
      Exane®-1069A
      Exane®-15 1168B Multi-Conductor 600V
      Exane® Case Wire
      Exane® 15 Reduced Dia. 600V
      Exane® ZH-1105A 600V
      Exane®ZH-1105A 2000V
      Exane®ZH-1105A 600/1000V Metric
      Exane®ZH-1105A 1800/3000V Metric
      Exane®ZH-1105A 1800V/3000V Metric
      1KV-DLO

      Telecommunications

      TelcoSafe® LIST 1
      TelcoSafe® LIST 2
      Intra-Bay Wiring
      TelcoFlex® II
      TelcoFlex® III
      TelcoFlex® IV

      Data

      Exane® RS-485
      Exane® CAT 6 4 Pairs 24 AWG
      Exane®Cat 5E 4 Pairs 24 AWG
      Exane® CAT 5E 2 Pairs 22 AWG
      Exane® MVB/WTB 4C 20 AWG
      Exane® MVB/WTB 2C 20 AWG

      Exane Compliance Certification

      Download this Sheet as a PDF

      Adobe Reader required.